Resilient, Efficient, SecureβDesigned as a System
Your on-prem data center (DC) is the beating heart of low-latency apps, regulated workloads, and edge/OT integrations.
SolveForce plans, builds, and operates DCs as a complete systemβpower, cooling, racks, cabling, network, storage, security, continuity, and observabilityβwired to evidence your teams and auditors can trust.
- π (888) 765-8301
- βοΈ contact@solveforce.com
Related hubs: π§ Fabric β /networks-and-data-centers β’ π’ Colo β /colocation β’ βοΈ Cloud β /cloud
π On-ramps β /direct-connect β’ π Optical β /wavelength / /lit-fiber / /dark-fiber
π― Outcomes (Why SolveForce for On-Prem DC)
- High-availability by design β A/B power, redundant cooling, dual fabrics, diverse routes.
- Deterministic low latency β leaf/spine cores, optical paths, storage fabrics tuned for Β΅s/ms budgets.
- Security & compliance β physical + logical Zero Trust with immutable evidence.
- Operational clarity β DCIM, SLO dashboards, runbooks, and clean handoffs to NOC/SecOps.
- Cloud-ready β private on-ramps, hybrid DR, and workload portability.
π§ Scope (What We Build & Operate)
- Power & Cooling β utility feeds, UPS (double-conversion), gensets, battery autonomy, CRAH/CRAC, hot/cold-aisle, liquid/immersion where needed.
- Racks & Distribution β cabinets/cages, PDUs (metered/switched A/B), busways, cable managers. β /racks-pdu
- Structured Cabling β SMF/MMF, Cat6A, MPO/MTP trunks, OTDR certification. β /structured-cabling
- Network Fabric β leaf/spine, 10/25/40/100/400G, EVPN/VXLAN, MACsec/L1 encryption options. β /networks-and-data-centers
- Storage & Compute β SAN/NVMe (FC/NVMe-TCP), virtualization, bare-metal & GPU clusters. β /san β’ /bare-metal-gpu
- Security β physical (mantraps, CCTV), NAC/802.1X, microsegmentation, ZTNA/SASE for admins. β /nac β’ /microsegmentation β’ /ztna β’ /sase
- Continuity β backups, immutability, DR tiers, failover runbooks. β /cloud-backup β’ /backup-immutability β’ /draas
- Observability β DCIM, environmental sensors, nets/links, storage & compute telemetry β NOC/SIEM. β /noc β’ /siem-soar
π§± Building Blocks (Spelled Out)
- Power: dual utility (where available) β dual UPS (N, N+1, 2N) β generator β A/B PDUs to every rack; load steps tested with load banks.
- Cooling: hot/cold-aisle, containment, economizers, liquid cooling for dense GPUs; thermal maps & alarms.
- Fire: VESDA + clean agent (FM-200/Novec 1230); zoned; documented discharge procedures.
- Fabric: EVPN/VXLAN leaf/spine, Anycast gateways, QoS lanes; out-of-band mgmt network.
- Optical: wavelength or dark fiber for DCI; route diversity & OTDR baselines archived. β /wavelength β’ /dark-fiber
- Security: RBAC, PAM for elevation, vault-managed secrets, HSM/KMS for keys, WAF/Bot at app edges. β /pam β’ /secrets-management β’ /key-management β’ /waf
ποΈ Design Patterns (Choose Your Fit)
A) Enterprise DC (General Purpose)
Redundant leaf/spine, SAN/NVMe tiers, virtualization + K8s, backup to object store with Object-Lock, DR to second site/cloud.
B) AI/HPC Pod in DC
High-density racks, liquid cooling, IB/RoCE fabrics, NVMe scratch + parallel FS, optical DCI; power/thermal SLOs for training windows. β /bare-metal-gpu
C) Regulated Enclave (PCI/HIPAA/CJIS/CMMC)
Physical cage, VRF + microseg, MACsec/IPsec, HSM keys, immutable logs & backups; ZTNA for admins; evidence packs. β /cybersecurity
D) Edge/Micro-DC
Short racks with rugged power/cooling, SD-WAN, ZTNA for ops, local compute + cache; backhaul over wavelength/fixed wireless. β /sd-wan β’ /fixed-wireless
E) Hybrid Hub (Cloud On-Ramp)
DC as meet-point: Direct Connect/ExpressRoute/Interconnect, BGP policy, Anycast services; WAF/Bot at perimeter. β /direct-connect
π SLO Guardrails (Targets You Can Measure)
SLO / KPI | Target (Recommended) |
---|---|
Power availability (A/B) | β₯ 99.99% rack-level |
Cooling delta (inlet temp p95) | Within ASHRAE envelopes |
PUE (annualized) | β€ 1.3β1.6 (site/region dependent) |
LeafβLeaf latency (p95) | β€ 10β50 Β΅s (in-DC) |
DCβDC latency (metro, one-way) | β€ 1β2 ms via wave/EPL |
SAN latency (p95) | β€ 300β800 Β΅s (FC/NVMe/FC) |
Change success rate | β₯ 99% (staged rings + rollback) |
Evidence completeness | 100% (as-builts, baselines, tests) |
SLO breaches open tickets and trigger SOAR (reroute, spread load, raise capacity, rollback). β /siem-soar
π Security & Compliance (Zero-Trust, Physical + Logical)
- Physical: mantraps, badges + biometrics, visitor logs, escorted access, camera retention.
- Logical: 802.1X/NAC on ports, ZTNA for consoles, microseg for east-west, PAM for admin flows, immutable logs.
- Crypto: TLS/mTLS/IPsec/MACsec/L1 as required; CMK/HSM, dual-control, KMIP. β /encryption β’ /key-management
- Data: DLP labels, tokenization, lawful residency; WAF/Bot & DDoS at boundary. β /dlp β’ /ddos
π Observability, DCIM & NOC
- DCIM: power, temps, humidity, door sensors, leak detection, camera states.
- Fabric: latency/jitter/loss, FEC/BER, light levels, buffer utilization, drops.
- Compute/Storage: CPU/GPU, memory, IOPS/latency, queue depth.
- Runbooks: alarm thresholds, escalation, maintenance windows; monthly SLA and capacity reports.
β /noc β’ /circuit-monitoring β’ /siem-soar
π΅ Commercials (What Drives Cost)
- Power density (kW/rack), redundancy tier, liquid vs air cooling, optics/fiber, racks/PDUs/cabling, security layers, DCIM, managed ops.
- Cross-connects, on-ramp ports, wavelength circuits, spares & maintenance, generator fuel contracts.
π οΈ Implementation Blueprint (No-Surprise Rollout)
1) Requirements β latency/throughput, kW/rack, growth, compliance.
2) Power & Cooling β A/B design, UPS/gensets, containment, liquid cooling plan.
3) Racks & Cabling β RU plan, PDU metering, trunk paths; label & OTDR certify.
4) Fabric & Storage β leaf/spine EVPN/VXLAN, SAN/NVMe tiers; QoS and jumbo MTUs.
5) Security β physical + logical Zero Trust; vault, HSM, WAF/Bot; logging to SIEM.
6) Continuity β Object-Lock backups, DR tiers, clean-point catalog; failover drills.
7) On-ramps β colo peering, DCβcloud paths, BGP policy & Anycast.
8) Baselines β load-bank, thermal, OTDR, RFC 2544/Y.1564, SAN perf; as-builts archived.
9) Operate β DCIM/NOC dashboards, capacity planning, patch/firmware windows, quarterly reviews.
β Pre-Engagement Checklist
- π Power: target kW/rack, autonomy, generator run time; redundancy tier.
- βοΈ Cooling: density, containment, liquid requirements, thermal limits.
- π§° Racks/PDUs: counts, RU plan, metering, busway vs whip.
- π§΅ Cabling: SMF/MMF/Cat6A specs, trunk counts, labeling standard.
- π§ Network: speeds, EVPN/VXLAN, MACsec/L1 needs, DCI routes.
- πΎ Storage/Compute: SAN tiers, GPU/AI plans, virtualization/K8s footprint. β /kubernetes
- π Security: NAC/802.1X, microseg, ZTNA/SASE, PAM, vault, HSM.
- πΎ Backup/DR: RPO/RTO tiers, Object-Lock scope, DR sites/cloud.
- π On-ramps: Direct Connect/ExpressRoute/Interconnect, cross-connects.
- π SIEM/NOC: dashboard set, reporting cadence, escalation matrix.
- π° Budget guardrails; managed vs co-managed operations.
π Where On-Prem DC Fits (Recursive View)
1) Grammar β compute/storage ride Networks & Data Centers & Connectivity.
2) Syntax β composes with Cloud and Colo for hybrid/DR.
3) Semantics β Cybersecurity preserves truth (identity, crypto, segmentation, evidence).
4) Pragmatics β SolveForce AI predicts risk/capacity/thermal envelopes and suggests safe changes.
5) Foundation β consistent terms via Primacy of Language.
6) Map β indexed in the SolveForce Codex & Knowledge Hub.
π Build an On-Prem DC Thatβs Fast, Secure & Auditable