A time-varying field in a dielectric carries a current no conductor carries — the displacement current, J_d = ωD — and the power a line carries travels in the field between its conductors, S = E × H. This calculator works both quantities as Book Two, Document A works them. From the voltage, frequency, separation, permittivity, and plate area you state, it returns E = V/d, D = ε₀εrE, J_d = ωD, the displacement current by both of the book’s paths — the field path I_d = J_d·A and the circuit path I = ωCV₀ — shown together, as the book checks one against the other, and Hφ(r) = (r/2)·J_d inside the dielectric. From a coaxial line’s stated voltage, current, radii, and permittivity, it returns the E, H, and S coefficients over r, the carried power by the integrated Poynting form and by the book’s terminal check P = V₀I₀, shown together, and Z₀ = (η/2π√ε_r)·ln(b/a). Every figure comes back with the stated state it was computed in.
The tool stands on two worked examples, each complete in its stated state: Book Two, Document A, Example 2.1 (V₀ = 100 V across d = 2 mm, εr = 4, at 10 MHz over 78.54 cm² plates — E = 50,000 V/m; D = 1.7708375 × 10⁻⁶ C/m²; J_d = 111.267 A/m²; I_d = 0.87389 A by the field path and 0.87390 A by the circuit path; Hφ(0.025 m) = 1.39084 A/m) and Example 2.3 (ln(3.5) = 1.252763; S coefficient 25.4087; P = 200.00 W; Z₀ = 51.84 Ω) — the tool’s figures standing at their own precision beside the book’s printed sets. Two states of the examples are carried exactly as documented: Example 2.3 stipulates V₀ = 100 V and I₀ = 2.0 A independently — their ratio is 50 Ω, not the line’s computed Z₀ — and the tool takes both as givens, never adjusting one to the other; and the example’s figures stand on the ratio b/a = 3.5, so the individual radii are your stated inputs, the default pair (a = 1 mm, b = 3.5 mm) disclosed in the tool as a measurement state — any radii at that ratio reproduce the example’s printed figures.
The book’s own placement of the second example is a communications one: its substrate is a coaxial communications line, and its results are the line’s carried power and characteristic impedance — the field quantities beneath the media a network is provisioned on. For SolveForce’s collective work the entry records the pillar Connectivity (coax and field fundamentals beneath provisioned media); no finder service is served directly, and that state is recorded rather than a mapping forced. The figures here are computed from the values you enter, at the state you enter; a line, fixture, or feed design for a specific installation is confirmed with a specialist for the site.
Ready when you are — run the numbers, or talk it through with a specialist.
Key terms in plain language
Open a term for a concise explanation of language used on this page.
VoIP
Voice over Internet Protocol carries phone calls over an IP network instead of a traditional analog phone line. Call quality depends on network stability, latency, and traffic management.
Unified Communications (UCaaS)
A cloud-based combination of business calling, messaging, meetings, presence, and collaboration tools managed as one communications service.
SIP Trunking
A service that connects a business phone system to the public telephone network using Internet Protocol, replacing or supplementing traditional phone lines.
Bandwidth
The amount of data a connection can carry in a given time, usually measured in Mbps or Gbps. More bandwidth supports more users, devices, and simultaneous applications.
Latency
The time it takes data to travel between two points. Lower latency improves voice, video meetings, cloud applications, gaming, and other real-time services.
Service-Level Agreement (SLA)
A provider’s written commitment covering service targets such as availability, response time, repair time, and sometimes financial credits when commitments are missed.