An electrode returning current to the earth raises the surface around it to a potential that falls with distance. Book Six Ch 42 §42.6.1 states that profile in the hemispherical earth-return geometry — VESP = ρI/(2πr) at radius r from an injection I into a crustal model of stated resistivity ρ — with its surface gradient E = V/r, and tabulates three crustal models at one shared state. State the model, the injection, and the radius, and the calculator returns the potential and the gradient; open the table mode, and the book’s three rows stand as printed, at their state; state a potential, and the inverse mode returns the quantity the form requires. Every result carries the standing it rests on.
The attested derived form: the potential of a hemispherical electrode in a homogeneous half-space, and the gradient the table’s own internal relation states. The page opens on the book’s granite state — ρ = 5000 Ω·m, I = 5000 A, r = 5 km — where the form computes 795.77 V against the table’s printed 795.7 V, a like at print precision. State your own model, injection, and radius and the profile follows; at the layered and conduit resistivities the ledger records the printed row’s ≈ 4× standing beside the form’s figure, and the table mode carries those rows as printed.
The ground: registry Entry 11 (Earth Surface Potential (ESP) Profiles), attested at exactly one position in the corpus — Book Six Ch 42 §42.6.1, the comparative ESP table and its surrounding sections (citation B6-R3), in the hemispherical earth-return geometry of Book Six Chs 39–42. The entry’s definition: the earth surface potential VESP at radius r from an earth-return electrode injecting current I into a crustal model of stated surface resistivity, with its gradient Er = −∂VESP/∂r. The hemispherical form V = ρI/(2πr) is the relation the register measures the table’s rows against; the table’s own internal relation states its E-field column as ESP/r at the stated r, and under the form the gradient’s magnitude ρI/(2πr²) is V/r identically — the two statements coincide. The entry’s grounding strength stands as the entry records it — Moderate: one table, fully stated states, its gradient column and one row verified exactly, two rows carrying an unstated factor — and its perpendicular correspondence is absence: no other book states an ESP profile. The tool states that ground rather than borrowing weight from its companion entry.
The entry’s unknown component, carried at its place: the layered and conduit rows stand at 3.999× and 4.002× the hemispherical form at their stated resistivities — the form returns 31.831 V and 1.5915 V at the table’s state, against the printed 127.3 V and 6.37 V — and the passage states no derivation for the ≈ 4× factor: no layering coefficient, no different effective radius. The factor is recorded as the rows’ documented state, not explained from outside. So the table mode returns the rows as printed and never scales them; the profile mode at those resistivities returns the form’s figure with the difference stated, never the factor applied; and the inverse mode does not invert a tabulated row. The granite row is a like at print precision — the form recomputes 795.77 V against the printed 795.7 V — and the gradient column is exact as ESP/r in all three rows at print precision: 795.7 V → 159 mV/m; 127.3 V → 25.5 mV/m; 6.37 V → 1.27 mV/m. The printings stand beside the computed standings at their precision, neither adopted as computed outputs nor resolved.
The companion standing, in both tools’ terms, unmerged: within Family II this page’s companion is Entry 10’s Grounding & Tolerable Voltage Calculator, which computes the IEEE Std 80 safety apparatus of a designed grid — the tolerable touch and step voltages at a selected body-weight state and fault duration, Sverak’s grid resistance, the ground potential rise, and the mesh and step voltages, with the pass/fail comparison. This page computes the surface potential profile of an earth-return electrode in a crustal model and the book’s tabulated crustal states. No member is shared: this page computes no tolerable voltage, no grid resistance, and no verdict on whether a potential may be stood on — the potentials it states are the quantities that apparatus bounds, and the bound itself is Entry 10’s, at its states. The entry’s own joining standing is positional: the ESP table stands in the same section (§42.6.1) as Book Six’s IEEE Std 80 threshold statement — the potential profile beneath the safety threshold. No value crosses with that standing: no tolerable voltage, body-weight constant, or duration state stands in this build, because Entry 11 attests none. The entry measures the grounding substrate from the geophysical discipline where Entry 10 measures it from the safety-standards discipline — one earth, two disciplines, two books. Its communications relation is a measured correspondence, marked as such — electrode siting and earth-return behavior are the ground side of facility and tower grounding; the book’s placement is a siting problem — and its pillar is Networks & Data Centers (site grounding), as that same measured correspondence, through Entry 10’s family. No finder is served directly; recorded. The keypad deck carries no ± key on this tool: every quantity the form states stands positive above zero — a resistivity, an injection, a radius, a potential — and the sign has no standing in its numerals.