Photovoltaic Module Calculator — the Single-Diode Parameter Set at STC

A photovoltaic module, stated as the books state it: Book Three’s b653 line, Ch 25, gives the single-diode parameter set entire — photocurrent, saturation current, ideality factor, series and shunt resistance — at Standard Test Conditions stated in full (irradiance 1000 W/m², cell temperature 25 °C, spectrum AM1.5G), for a 60-cell monocrystalline module. Section 1 works the set’s own consistency: the open-circuit voltage the set implies, by the book’s open-circuit equation. Sections 2 and 3 run the entry’s reeled-out derivation — the single-diode solver the schema points to: the operating point at your stated voltage, and the curve’s named states.

Section 1 — The Parameter Set & the Open-Circuit Voltage

The set stands in the fields as the book states it. The open-circuit voltage is returned by both of the equation’s documented paths together: the book’s open-circuit condition with the shunt term standing in it, solved; and the closed form with the shunt term standing aside.

A
×10exp A
exponent
no unit
Ω
Ω
cells
K
—

The set’s line state is part of its identity: the set stands in Book Three’s b653 line, Ch 25; the parallel 4049 line treats the same models without the stated set and does not carry it, so the schema stands on the one line’s attestation, in its line state. The thermal voltage stands on the SI defining constants, exact: kB = 1.380649 × 10−23 J/K and q = 1.602176634 × 10−19 C. One further standing of this relation stands recorded at its place, not computed here: Book Eight states the diode relation’s operating members in the thermophotovoltaic identity — the relation at work on an emitter’s radiation, without this set’s STC state and without its Rs/Rsh pair. That is a different identity from this page’s schema, and nothing of it is this page’s ground.

Section 2 — The Operating Point

The solver is the entry’s reeled-out derivation, marked as derivation: the books attest the parameter set and its open-circuit consistency, not a worked I–V solution. At the terminal voltage you state, the solver returns the point on the set’s own curve — the diode and shunt branches shown at their figures.

V
—

Section 3 — Short Circuit, Maximum Power & the Characteristics

The curve’s named states, from the same solver: the short-circuit current by the equation and by the circuit’s resistive division together; the maximum-power point as one computed state; the fill factor FF = Pmax/(Voc·Isc); and the efficiency η = Pmax/Pin at a stated irradiance.

W/m²
m²
—

The five measurables of the page’s extension stand in Sections 1 and 3: Voc from the diode equation at the stated parameters; the Isc state; the maximum-power operating point as one computed state; the fill factor; and the efficiency at a stated irradiance. The page stands on Book Three alone: no other book states a photovoltaic parameter set — the registry’s perpendicular correspondence for this entry records the absence, and the set is not completed from any other book’s figures.

For the figures: select a field, then tap the keys — or type as usual. The ± key sets the sign of the figure in the field — the saturation current’s power of ten is a signed state.