Magnetic Strength — Gauss & Tesla

Flux density in both systems, the field strength it corresponds to in free space, and the field a current makes.

Convert flux density (B)

—

Field of a long straight conductor — B = μ0I ÷ 2πr

amperes

Field inside a long solenoid (air core) — B = μ0nI

turns
amperes

Field inside a toroidal coil — B = μ0NI ÷ 2πr

turns
amperes

The directions on a torus have their own names. The torus is the surface made by revolving a circle (the minor circle) about an axis in its plane; the path the minor circle’s centre traces is the major circle. Toroidal is the direction around the torus’s central axis, following the major circle — the path encircles the hole; it does not pass through it. Poloidal is the direction around the tube’s cross-section, following the minor circle, in the plane of a section cut through the axis. Helicoidal combines winding with advancement, as a screw thread runs; where a field line carries toroidal and poloidal components together it is helicoidal, winding around both directions, and its pitch may vary along the path. The direction of the field is not the direction of the wire, and the two are kept apart here: in the idealized current-component relationship, a poloidal current — the winding passing around the tube — produces a toroidal field, and a toroidal current produces a poloidal field.

The toroidal formula above is the ideal model: a uniformly wound, air-core toroid. Its r is the distance from the central axis to the evaluation point inside the winding region — the major-axis radius, not the tube radius — and the field falls as 1/r across the core’s cross-section, stronger at the inner edge. Zero field outside the core belongs to the ideal model; a practical winding leaks, and its field also depends on its return path, its spacing, its geometry, and its magnetic material. At the defaults above — 500 turns, 2 A, r = 10 cm — the model gives B = 0.002 T = 2 mT = 20 G. The solenoid above is a helicoidal winding on a cylinder; the toroid is the same helix closed into a ring. The two directions are counted against each other by turns: q counts the toroidal turns per poloidal turn, and the rotational transform ι counts the poloidal turns per toroidal turn, so ι = 1/q. The transform is dimensionless; a screw’s pitch, by contrast, is a length per turn.

“Magnetic strength” names two quantities, and they are kept apart here. Magnetic flux density (B) is what the gauss measures: its SI unit is the tesla (T), and its CGS unit is the gauss (G), named for Carl Friedrich Gauss — 1 G = 10−4 T, exactly. Magnetic field strength (H) is measured in amperes per metre (A/m), or in CGS in oersted (Oe), with 1 Oe = 1000/4π A/m ≈ 79.5775 A/m. The two are related by B = μ0(H + M); in vacuum M is zero, so B = μ0H, with μ0 = 4π × 10−7 H/m as this tool’s working constant — in the modern SI, μ0 is an experimentally determined constant, and the conventional value here is the one this tool’s stated benchmarks are computed in — which is why, in free space and to working accuracy in air, a flux density of 1 G corresponds to a field strength of 1 Oe. Inside a material the two separate, because B there depends on the material’s permeability. The conductor’s field circles it by the right-hand rule and falls with distance; the solenoid’s formula is the ideal long-solenoid value at its centre, and a ferromagnetic core multiplies it by the core’s effective permeability, which this tool does not assume — a constant permeability is itself an approximation, and saturation and hysteresis need a material-specific model. For scale, as typical values rather than measurements: Earth’s field runs about 0.25–0.65 G (25–65 µT) by location, a refrigerator magnet’s surface field is on the order of 50 G, and clinical MRI magnets run at 1.5 T and 3 T — 15,000 G and 30,000 G.

For the figures: select a field, then tap the keys — or type as usual.